If it's advanced--It's MHI!
Home

Customer Appreciation Specials
* Request A Quote
*
Technical Articles
* Products Login *

Products

   ----------------------

R&D Services

   ----------------------

Technical Articles
*Conversion Calculator*

 

         About MHI


 
Temperature
Converter

Enter a number
& click on
the "Calculate" button

°F= °C

 

  Technical Articles
*Conversion Calculator*

Useful Links

LT Airtorch™ (LTA)
Max. use 925°C and below
Airtorch™ (AT)
750°C - 1300°C
Ultra and Plasma Airtorch™
1000°C - 1500°C

LTA(850°C)

SLTA (800°C)

Die Heating

Model - 0.5kW

Model - 6.5kW

Model - 15kW

AT-PV

Model - 1kW

Model - 10.5kW

3 Phase 20,30,60kW

Model - 3kW

Convective Heat Treating

Typical Applications

Model 3kW

Model 6.5kW

Ultra Airtorch™
(1500°C)

Recirculating Airtorch

Engineering Conversion Charts

Technology and Applications



LTA
850-900°C max temp
use with compressed air or gas

For Higher temperature  use MTA925 or AT models

VTA
750°C max temp
(VTA's use integral fans and blowers)


New GTA Models (Low to High kW also available in high pressure configurations). Click here.

click here for GTA

LTA MODELS

Model   Power Voltage Phase Max Temp
Maximum air flow for max. rated temp.  *

Control Panel

(optional)

Availability of temp. indicator box
**

(optional)

Diameter

of

heater tube

Height

of system

Air/Gas Supply

which may be used

Inlet Exit BUILT-IN  T/C
LTA 750 - 01 (ver2) 1kW 115/120 1 850C 1.4 CFM BPAN TI 2.1"
(53 mm)  

15.25"

(387 mm)

Compressed Air 1/4" NPT 1/4" NPT Type "K"
LTA 750 - 02 2kW

208/220/230/240

special order for 115/120

1 850C 2.8 CFM BPAN TI

3.3"

 (86 mm)  

14.75"

(374 mm)

Compressed Air 1/4" NPT 1/2" NPT Type "K"
LTA 750 - 04 4kW 220/230/240 1 850C 5.6 CFM BPAN TI 4.0"    
(100 mm)
18.5"
(470 mm)
Compressed Air 1/2" NPT 2" NPT Type "K"
LTA 750 - 06 6kW 220/230/240 1 850C 8.4 CFM BPAN TI 7.0"   
(178 mm)  
23.1"
(587 mm)
Compressed Air 1/2" NPT 2" NPT Type "K"
LTA 750 - 10
10kW
220/230/240 1 850C 14 CFM
HIPAN
TI 7.0"  
(178 mm)  
23.1"
(587 mm)
Compressed Air 1/2" NPT 2.0" NPT Type "K"
LTA 750 - 12 12kW 220/230/240

1

850C 16.8CFM

HIPAN

TI 7.0"  
(178 mm)  

23.3"

(593 mm)

Compressed Air 3/4" NPT 2.5" NPT Type "K"
LTA 750 - 24 24kW 440/480 3 850C 33.6CFM
TRIPAN
TI 10.1"   
(257 mm)  

23.3"

(593 mm)

Compressed Air Flanged 4" dia pipe Flanged 4" dia pipe Type "K"
LTA 750 - 36
36kW
415/440/480 3 850C 50.4 CFM
TRIPAN
TI Call 

Call

Compressed Air Flanged 4" dia pipe Flanged 4" dia pipe Type "K"
LTA 750 - 48
48kW
415/440/480 3 850C 67.2 CFM
TRIPAN
TI Call 

Call

Compressed Air Flanged 4" dia pipe Flanged 4" dia pipe Type "K"
LTA 750 - 60
60kW
415/440/480 3 850C 84.0 CFM
TRIPAN
TI Call 

Call

Compressed Air Flanged 4" dia pipe Flanged 4" dia pipe Type "K"
                         48kW and higher available also please call MHI.  Note that dimensions are to be read within a tolerance.  Please call MHI.
  *  This is also minimum airflow required when energized.
 
** TI: Temperature indicator     

For LTA's please note above BPAN and RPAN's provide full PID control of temperatures.
TI is not a power controller but only a temperature read -out.

FOR VTA's fan control is available with the FANCS which also has the temperature controller.
 For a picture of the FANCS Unit please see pictures below.

VTA MODELS

Model  
Power
Voltage
Phase
Max Temp
Maximum air flow for max. rated temp.  *

Control Panel
**

(optional)

Dia
Height
AIR SUPPLY

Inlet

integrated with fan

Exit
GRIPPER
 BUILT-IN    T/C
PROTECTIVE GUARD
        MECHANICAL DIMENSIONS   AIR CONNECTION    
VTA 750-1GC
1 kW

115/120

1
750C
1.3 CFM
FANCS

2.1"
(53 mm)  

19.75"
(501.65 mm)
Fan model: 4C443
Fan
1/2" NPT
Yes
Type "K"
Yes
VTA 750-2GC
2 kW

220/230/240

1
750C
2.6 CFM
FANCS

3.15"
(80 mm)

21.65"
(550.0 mm)
Fan model: 2C647
Fan
1" NPT
Yes
Type "K"
Yes
VTA 750-4GS
4 kW
220/230/240
1
750C
5.2 CFM
FANCS

4.0"  

(100 mm)  

27.5"
(698.5 mm)
Fan model: K4XL
Fan
2" NPT
No
Type "K"
No
VTA 750-6GS
6 kW
220/230/240
1
750C
7.8 CFM
FANCS

7.0"
(177.8 mm)  

27.5"
(698.5 mm)
Fan model: K6XL
Fan
2" NPT
No
Type "K"
No
3-phase VTA's with fans up to 300 kW  60 - 300kW  240/440/480  3  700C  variable  TRIPAN
call MHI
** : FANCS: Fan speed controller and temperature indicator
* This is also minimum airflow that must be maintained always when energized.

Several typical LTA (1kW) models (inline) and VTA (4kW and 1kW) units with integral fans/blowers shown below. Please contact MHI for assistance.

 

     


Please contact MHI for flow rate-temperature diagrams,
details, complete specifications or custom high power units.

FANCS UNITFANCS UNITAirtorch adaptors

FANCS UNIT                                  ADAPTORS


LTA Airtorch™ Heater Accessories
NPT Nozzle NPT Nozzle with fitting for pipe extension
Knife Nozzle Knife Nozzle

FS750-A - Adjustable flow rate detection valve and switch
FS750 - Flow rate detection valve and switch
FLM750 - Flowmeter 2-23 SCFM (click for larger images)
FTB750-6 - 6' Air/gas supply tubing
MTAR - Moisture trap ensures dry air to AirtorchTM


Secure MHI Store

(only select products can be now bought on-line)

 

Copyright © 2000 - 2008  MHI, Inc. All rights reserved.